TC 886

Application:

  • The capacitors TC 886 are determined especially for start of alternating-current asychronous motors which can be energized from mono phase or three phase network.

 

Electrical properties:

  • Nominal capacitance: 1,5 µF to 100 µF
  • Tolerance of capacitance: ±10%(K), ±5%(J)
  • Nominal voltage: Un 500 Vac 50Hz
  • Test voltage between terminals: 2 x Un 50Hz/60s
  • Test voltage between terminals and case: 2000V 50Hz/60s

 

Type marking of capacitors:


1st letter indicated type of terminals

  • M . . . single faston tag 2,8 x 0,5 mm (only for Ø D = 25 mm)
  • J . . . single faston tag 6,3 x 0,8 mm
  • X . . . single faston tag 6,3 x 0,8 mm not standardly turned
  • D . . . double faston tag 2 x 6,3 x 0,8 mm
  • H . . . outlet cable, lenght 250 mm
  • L . . . insulated flexible wire outlets, cross section 0,75 mm2, lenght 200 mm (except Ø D = 45, 50 and 55 mm)
  • I . . . insulated wire outlets, Ø 0,8 mm, lenght 210 mm (except Ø D = 45, 50 and 55 mm)


2nd letter indicates case fixing system

  • B . . . case without a base stud M8 x10 mm
  • S . . . case with a base stud M8 x 10mm (a nut and a washer are included)

 

Example of marking for an order:

  • TC 886DB 5µF ±10% - motor capacitor for start of asynchronous motors in plastic case without a base stud, outlets are made with double faston tags, capacitance is expressed in µF with tolerance ±10% .

Technical data sheet

TM 471

Application:

  • MKP capacitors 471 are determined for start and operation of single phase or three phase asynchronous motors, which are single phase energized. They can operate in permanent operations as run capacitors.

 

Electrical properties:

  • Nominal capacitance: 2 to 60 µF
  • Tolerance of capacitance: ± 10% ( K ) , ± 5% ( J )
  • Nominal voltage: Un 480 Vac 50Hz
  • Test voltage between terminals: 2 x Un 50Hz / 60s
  • Test voltage between terminals and case: 2000V 50Hz / 60s

 

Type marking of capacitors:

 

1st letter indicates type of terminals

  • J . . . single faston tag 6,3 x 0,8 mm
  • D . . . double faston tag 2 x 6,3 x 0,8 mm (except Ø D = 30 mm)
  • E . . . soldering tags without a discharging resistor
  • K . . . outlet cable with pressed protective cap

 

2nd letter indicates case fixing system

  • B . . . case without a base stud
  • S . . . case with a base stud M8 x 10mm (a nut and a washer are included)

 

Example of marking for an order:

  • TM 471 JS 20 µF ± 5 % - motor capacitor for start and operation of single phase or three phase asynchronous motors in an aluminium case with a base stud, outlets are made with single faston tags. Capacitance is expressed in µF with tolerance ±5 %.

Technical data sheet

TM 451

Application:

  • MKP capacitors TM 451 are determined especially for start of asynchronous motors. They can operate as motor run capacitors in permanent operations.


Electrical properties:

  • Nominal capacitance: 16 to 220 µF
  • Tolerance of capacitance: ±10%(K), ±5%(J)
  • Nominal voltage of starting operation: Un 350 Vac 50Hz
  • Nominal voltage of permanent operation: Un 250 Vac 50Hz
  • Test voltage between terminals: 2 x Un for permanent operation 50 Hz / 60 s
  • Test voltage between terminals and case: 2000 V 50 Hz / 60 s


Type marking of the capacitors:


1st letter indicates type of terminals

  • H . . . outlet cable, lenght 250 mm, goes completely through an axial-plastic cover


2nd letter indicates type of terminals

  • B . . . case without a base stud M8 x 10 mm
  • S . . . case with a base stud M8 x 10mm (a nut and a washer are included)


Example of marking for an order:

  • TM 451 HB 100 µF ± 10 % - motor start capacitor for start of asynchronous motors in a plastic case without a base stud, with outlet cable. Capacitance is expessed in µF with tolerance ±10%.

Technical data sheet

34

Application:

  • MKP capacitors TC 851 and TC 853 are determined especially for asynchronous motors, which can be energized from mono phase or three phase network. These capacitors are also suitable for other application e.g. in DC circuits. MKP capacitors can operate in permanent operations as run capacitors or in intermittent operation. Intermittent operation can be arranged with a customer.

 

Electrical properties:

  • Nominal capacitance: 0,1µF - 10µF ( TC 851 ) 0,1µF - 5µF ( TC 853 )
  • Tolerance of capacitance: ±10%(K), ±5%(J)
  • Nominal voltage: Un 250 Vac 50Hz ( TC 851 ) Un 400 to 450 Vac 50Hz ( TC 853 )
  • Test voltage between terminals: 2 x Un 50Hz / 60s
  • Test voltage between terminals and case: 2000V 50Hz / 60s


Type marking of the capacitors:


1st letter indicates case fixing system

A … case is suitable for PCB
B … case with holder for screw M4 2nd letter indicates type of terminals
1 … outlet wire Ø 0,8mm, length 6mm
2 … insulated wire 0,75mm2 , length 110mm
3 … single soldering tags 
4 … spade connector 6,3 x 0,8mm
5 … spade connector 4,8 x 0,8mm
7 … insulated wire Ø 0,8mm, length 110mm

 

Example of marking for an order:

  • TC 853 B7 5µF ± 10% 450V motor capacitor for asynchronous motors in plastic case with holder and with a wire insulated terminals. Capacitance is expressed in µF with tolerance ± 10%. It is necessary for order to complete combination of letter and number. The type number is not valid without the extension.

Technical data sheet

 

logo_ISOx  logo_ROHSxlogo_PBx

Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen

Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen

Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen

Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen

Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen
Tenkovrstvá technologie, Kondenzátory, Odrušovací prvky, Harlingen